Page 101 - Demo
P. 101


                                    Fairbank Equipment, Inc. www.fairbankequipment.com E99ELECTRONICSTEEJET SENTRY 6141 & 6140SENTRY 6141 ISOBUS TIP FLOW MONITORReliable Detection of Plugged Tips in a New, ISOBUS Compatible DesignPlugged or partially blocked spray tips can have a significant impact on thequality of your application. Streaks in the field caused by misapplication canresult in yield reductions, increased weed pressure and the need to re-apply- all of which can be costly. The Sentry 6141 Tip Flow Monitor provides asimple, reliable solution to this age-old problem. Flow sensors mountedat each spray tip location monitor the flow through the tip and provideinstantaneous feedback to the operator should a tip become clogged. Byeliminating the need to detect plugged tips visually from the cab, operatorscan cover more acres in a day, and know, with confidence, that their sprayer,planter or fertilizer applicator is operating properly.FEATURES & BENEFITS:%u2022 Individually monitor flow performance from every spray tip or metering orifice on your equipment.%u2022 Sentry 6141 utilizes a compact flow meter integrated into  each nozzle body.%u2022 With an ISOBUS compatible design, Sentry 6141 can connect to an existing TeeJet or third party Universal Terminal (UT) and eliminates the need for an additional console in the cab.%u2022 Flow meter detects flow variation caused by clogs, nozzle damage or loss, or upstream flow restrictions.%u2022 System can monitor up to 120 spray nozzles simultaneously.%u2022 Error is indicated by audible alarm, display notification and illuminated LED at the affected nozzle.%u2022 Flow meters rated from 0.15-2.5 GPM (0.6-9.5 l/min) and maximum pressure of 150 PSI (10 bar).illuminated LED at the affected nozzleCall for Details & Current PricingThe turbine style flow meter used with the Sentry 6141 Tip Flow Monitoris compact, reliable and proven. The threaded connection allows thesensor to be added onto a wide range of standard TeeJet single andmultiple outlet nozzle bodies. ChemSaver%u00ae diaphragm check valvesremain in place to provide positive spray tip shutoff. Ample clearanceinside the flow meter means minimal flow restriction and generous freepassage for particles contained in the spray solution. Long wearingmaterials are used in bearing surfaces to ensure a consistent flowreading. The flow meter sensor is mounted externally to prevent directcontact with the spray solution for long-term reliability.Call for Details Current PricingSENTRY 6140 TIP FLOW MONITOR%u2022 Individually monitor flow performance from every spray tip on your boom.%u2022 Sentry 6140 utilizes a compact flow meter integrated into each nozzle body.%u2022 Flow meter detects flow variation caused by clogs, nozzle damage or loss, or  upstream flow restrictions.%u2022 System can monitor up to 75 spray nozzles simultaneously.%u2022 Error is indicated by audible alarm, display notification and illuminated LED at the affected nozzle.%u2022 Flow meters rated from 0.1-2.5 GPM (0.4-9.5 l/min)  and maximum pressure of 150 PSI (10 bar).
                                
   95   96   97   98   99   100   101   102   103   104   105