Page 348 - Demo
P. 348


                                    A346 Fairbank Equipment, Inc. www.fairbankequipment.com SAFETY & DECALSCAUTION ANHYDROUS AMMONIA (Under Pressure)READ CAREFULLY2. STAND \ EQUIPMENT.1. KEEP AWAY FROM POP-OFF VALVE MARKEDTHIS IS A SAFETY DEVICE AND SHOULD NOT BETAMPERED WITH OR ADJUSTED.3. WEAR GOGGLES AND RUBBER GLOVES WHENTRANSFERRING PRODUCT AND \4. WEAR GOGGLES AND RUBBER GLOVES WHENTRANSFERRING PRODUCT AND \5. NEVER USE VALVE HANDWHEEL AS A HOSE HANDLE.6. BLEED HOSE END VALVES BEFORE STARTING TO DISCONNECT.8. DO NOT PERMIT CHILDREN NEAR THIS EQUIPMENT.7. CLOSE VALVE FIRMLY BUT DO NOT USE WRENCH OR PLIERS.9. PARK EQUIPMENT AWAY FROM BUILDINGS OR ANY POSSIBILE FIRE HAZARDS. NEVER ALLOW TANKS TO BE SUBJECTED TO EXTREME HEAT.10. DO NOT ATTEMPT ANY REPAIRS OF THIS EQUIPMENT. IN EVENT OF ANY FAILURE CALL YOUR DEALER IMMEDIATELY.11. DO NOT OPERATE THIS EQUIPMENT UNTIL YOU HAVE RECEIVED INSTRUCTIONS FROM YOUIR DEALER.EMERGENCY FIRST AIDSHOULD LIQUID OR VAPORS OF THIS PRODUCT COME INCONTACT WITH EYES OR SKIN--2. REMOVE IMMEDIATELY ANY CONTAMINATED CLOTHING.1. FLUSH AFFECTED AREA THOROUGHLY WITH WATER FOR 15 MINUTES.3. DO NOT APPLY SALVES OR OINTMENTS TO BURNS. GET TO DOCTOR AS SOON AS POSSIBLE.PULLING SPEEDMAXIMUM.H. 25 M.Pehicle Responsible Pulling VANHYDROUSAMMONIA10052LIQUIDVAPORFIRST AIDWATERWEAR YOURO LESRequirements Per Nurse Tank By StatePart No. Kansas Nebraska Oklahoma ColoradoWFAD 1 1 1 1NH3S-R 2 2 2 2NH3C-R 2 2 2 2SLD 2 2 2 2SVD 1 1 1 1IH-2 2 2 21005-NH3 4 4 4 425MPH 1 1FAWD 2 2 2 2WYG 1 1 1 12FS 1 1 1V-00 1 1 FILL HOSELIQUID OUT PRESSURELIQUID OUT VALVEFILL VALVEHOSE VALVESAFETY VALVESUPPLY TANKAPPLICATOR TANKNOTE: Valves May Be Combined%u0090 or Arranged DifferentlyVAPOR VALVEHOSE BLEEDOR BLEEDTO REGULATOR GAUGE100150 25050 3500 40040020012 43TRANSFER INSTRUCTIONS APPLICATION INSTRUCTIONSFIRST AID SUGGESTIONSSEE PHYSICIAN IN ALL SEVERECASES OF AMMONIA BURNSSAFETY SUGGESTIONS FORNH3 IS SAFE IF HANDLED PROPERLYAMMONIA HANDLINGB. To Disconnect Hose (Not applicable where transfer pumps are%u0090 used.)%u0090 1. Open hose bleed - BE SURE HOLE IS AWAY FROM YOU-%u0090 and allow to empty.%u0090 2. Disconnect hose from applicator tank - replace protective cap.%u0090 3. Carefully rack hose on supply tank to avoid kinking and%u0090%u0090 dragging on ground.A. To Fill Applicator Tank (Not applicable where transfer pumps%u0090 are used.)%u0090 1. Check hose and valve connections for dirt, and valves for%u0090 connection seal washers. Connect fill hose (hand tight only) to%u0090 applicator fill valve (1).%u0090 2. Be sure hose bleed is closed - then open valves (1), (2), (3) &%u0090 (4) in succession. Note: Valve (1) automatically opens and%u0090 closes on some applicators.%u0090 3. Maintain not over 10 - 15 lbs. lower pressure in applicator by%u0090 adjusting vapor valve or bleed (3)-- fill applicator to only 85%%u0090 as shown by spewing of liquid ammonia from vapor or%u0090 bleed (3).%u0090 4. Immediately close valve (4)-- after 30 seconds close valves%u0090 (3), (2) & (1) in this order. 1. Set regulator, according to make, for desired output, swath,%u0090 tractor speed, etc.%u0090 2. Start tractor moving - drop knives to desired depth and turn%u0090 on NH3.%u0090 3. Maintain constant speed - shut off NH3 one tractor length from%u0090 row end - lift knives before turning.%u0090 4. Periodically check to be sure correct amount of ammonia has%u0090 been applied for acreage covered.%u0090 5. Periodically check knife hoses for frosting which indicates%u0090 full flow.%u0090 6. Adjust regulator as necessary and clean strainers according%u0090 to instructions.LARGE VOLUMES OF FRESH WATER CONSTITUTE THE%u0090 BASIC FIRST AID TREATMENT FOR AMMONIA BURNS.%u0090%u0090SKIN CONTACT%u0090 A. Immediately flood affected area with water. B. Remove af-%u0090 fected clothing. C. Reflood and leave affected skin open to air.%u0090EYE CONTACT%u0090 Immediately flood eye with abundance of fresh water for at%u0090 least 15 minutes and repeat.%u0090MOUTH & THROAT CONTACT%u0090 Rinse, gargle and drink large quantities of water or lemonade.%u0090VAPOR CONTACT WITH LUNGS%u0090 Move to fresh air. Avoid violent or unskilled artificial respiration.%u0090INTERNAL CONTACT%u0090 Neutralize ammonia with abundance of vinegar or lemon juice.%u0090 Follow with raw eggs, cream or olive oil to protect tissues.%u0090  %u2022 Use only approved ammonia equipment in first-class condition.%u0090 %u2022 Call your dealer immediately in case of leaks, malfunction or%u0090 exceptional wear.%u0090 %u2022 Do not tamper with valves or equipment except as instructed.%u0090 %u2022 Stay upwind when filling. Sniff, don't breathe deeply when%u0090 approaching area.%u0090 %u2022 Ammonia gloves and goggles should be worn when transferr-%u0090 ing ammonia.%u0090 %u2022 Keep out of a direct line from openings on all valves and%u0090 fittings.%u0090 %u2022 Before removing hoses or parts, be positive all pressure is%u0090 out of the system.%u0090 %u2022 Never pick up a hose by the valve hand wheel nor allow valve%u0090 contact with ground.INHALATION HAZARDANHYDROUS AMMONIAAlso available in steel, part no. #2 Steel NFPA-704-3-NH3 Storage Plant DecalSAFETY DECALSSee last page of Ammonia section for Nurse Tank Decal layout.Decal Sets by State Custom Decal%u2019s Available,Fax Your Request for a Quote.Your Company NameEmergency Phone NumberSTATE PART#Kansas FB-DECAL-PKG-KSNebraska FB-DECAL-PKG-NEOklahoma FB-DECAL-PKG-OKColorado FB-DECAL-PKG-CO
                                
   342   343   344   345   346   347   348   349   350   351   352